GB
|

|
|
DC/DC
Chassis Mount 30W & 60W |
- Input voltage options:12V,24V
and 48VDC
- Other inputs on request
- Low profile,,fully encapsulated
module
- Ideal for harsh environments
- Adjustable output
- Overcurrent protection
- High operating temperature range
+70 °C
- Input - output isolation
- Low cost non-isolated units on
request
- Suitable for a wide range of
industrial applications
- Special low cost non-isolated
models on request
- 110V DC input options
|
|
|
|
SF30
|

|
|
DC/DC
Chassis Mount 30W |
- Wide DC Input 4:1 Range
- Very compact chassis mount with
screw terminal connection
- Low profile, fully encapsulated
module
- Ideal for harsh environments
- Overcurrent protection
- High operating temperature range
+70 °C
- Input - output isolation
- Suitable for a wide range of
industrial applications
|
|
|
|
GB2
|

|
|
Single
Output , Compact 120W |
- Wide range of input options
- Convection cooled: No fans
- Low profile 40mm
- Fully encapsulated, ideal for harsh environments
- Fully isolated input – output
- Over voltage protection
- Overload and short circuit protection
- Suitable for a wide range of applications
- MTBF > 200,000hrs
- Special input / output combinations on request
- Battery Charging options: Consult office
|
|
|
|
SDC
|

|
|
Single
, Dual , Tripple
Output , Compact 5W - 60W |
- Standard
input 2:1 or wide Input
4:1
- Input
voltages: 5V , 12V, 24V
and 48V
- Single,
Dual and Triple output options
- Screw
terminal connector
- Short
Circuit & OVP protection
- High
operating temperature up
to 70°C
- Low
Ripple & Noise
- Suitable
for a wide range of telecom
and industrial applications.
- Chassis
mount or Din rail mount
|
|
|
|
SWY
|

|
|
Single
Output , Encapsulated , 30-150W |
- 30,
60, 90, 100, 120 or 150W
output power
- Wide
input range ( 72V or 110V
nominal )
- Ideal
for harsh environments including
railway applications
- Transient
protection ,
- Complete
encapsulation , Conduction
cooling
|
|
|
|
GXR
|

|
|
DC/DC
Single Output 70W |
- Switchmode design.
- 3 wide input
ranges: 10-16V, 21-60V and 60-132V.
- Standard output
voltages: 13.8V, 24V and 48V.
- Compact and
lightweight.
- High efficiency
- Typically 80 - 85%.
- Full Galvanic
Isolation.
- Fully isolated, i.e.
Input/Output can be +ve or -ve with respect to the other.
- Input potential cannot
appear at the output
- Low noise.
- Short circuit
protection.
- Reverse polarity
protection.
|
|
|
|
GHR
|

|
|
DC/DC
Single Output 150W |
- SwitchMode
design.
- 3 wide input ranges:
10-16V, 21-60V and 60-132V.
- Standard output
voltages: 13.8V, 24V and 48V.
- Compact and
lightweight.
- High efficiency - Typically
80 - 85%.
- Full Galvanic
Isolation.
- Fully isolated, i.e.
Input/Output can be +ve or -ve with respect to the other.
- Input potential cannot
appear at the output.
- Low noise.
- Short circuit
protection.
- Reverse polarity
protection.
|
|
|
|
SV
|

|
|
Single
Output , Compact 15W - 50W |
- Option of 12V,24V,48V or 110VDC
input
- Wide input range
- Three power levels 15,25 and
50 watts
- Floating output
- Input – Output fully isolated
- Fully regulated
- Overload and Overvoltage protection
- Demonstrated High MTBF 740,000
hrs
- No fan cooling
- Smart compact chassis mounting
case
- Voltage adjustment trim potentiometer
- Suitable for a wide range of
telecom and
- industrial applications.
|
|
|
|
VT
|

|
|
Single
/ Multi Output , 15W - 150W |
- Wide range of DC input options
- 12V,,24V,48V and 110 VDC
- Filtered to meet EN55022 EMI
- Fully isolated input -output
- Vented case with screw terminal
connections
- Overload protection
- Overvoltage protection
- MTBF 100,000 hours
- Inrush current limiting
- Convection cooled -no fans
- Suitable for a wide range of
industrial and
- telecom applications
- N+1 redundancy options
- Single,dual and triple output
models
|
|
|
|
GCW
|

|
|
Wide
Input DC/DC 100W or 200W |
- Wide input,,20~60 VDC or 85-160VDC
- Suitable for 24V and 48V input
applications
- Customised input voltages on
request
- Filtered to meet EN55022 Class
B EMI
- Fully isolated input --output
1500 VDC
- Open frame or vented case option
- Double regulator overvoltage
protection
- Overload protection
- MTBF 100,000 hours
- Inrush current limiting
- Special output voltages up 120V
on request
- 150W available as a Eurocard::
- 3U x 10HP x 160mm
|
|
|
|
MDS
|

|
|
DC/DC 15W - 350W |
- 2:1 Wide Input Range
- 1500VDC I/O Isolation
- Short circuit / Overload
/ Over Voltage Protection
- Over temperature
protection for models 200W and 350W
- Built in EMI filter
for models 15W to 150W
- 100% full load burn
in test
- Low Cost and High
reliability
- Convection cooled
for models from 15W to 200W
|
|
|
|
T3
|

|
|
DC/DC
Single Output 300W |
- Wide input non--isolated DC-DC converters
- Step--down and step-up models
- High efficiency typically 90%%for
24/12V model
- Open frame or cased options
- Offers off the shelf solutions
for non--standard DC-DC
- applications
- Low noise EN55022B
- Overload protection
- Over temperature protection --auto
recovery
- Remote sense T3M and T3 step
down models
- Option E =Tropicalised
- Option M =Ruggedised
- High MTBF 500,000 hours
|
|
|
|
OR1
|

|
|
DC/DC
Single Output Non Isolated 60W - 830W |
- Models with 12V and
24V input
- Wide range suitable
for mobile applications
- Non isolated step
up and step down models
- Convection cooled
up to 240W
- Some models suitable
for battery charging
- Parallel operation
for increased power possible
|
|
|
|
OR2
|

|
|
DC/DC
Single Output Isolated 100W - 360W |
- SwitchMode
design.
- full
galvanic isolation.
- Input
voltages: 12V , 24V
, 48V , 96V.
- Output power levels: 100W
, 200W
and 360W
- Output models suitale for 24V battery charging
- High
efficiency
.
|
|
|
|
|