GEN
|

|
|
750W
or 1500W or 3300W, 1RU or 2RU programmable |
- Universal input 85~264 VAC
- Active Power Factor Correction 0.99
- High power density 1500W in 1U rack
- Output up to 600V, current up to 200A
- Built in RS232/RS485 interface - standard
- Optional GPIB (SCP) interface
- Software calibration and Last Setting Memory
- High resolution 16 bits ADCs and DACs
- Reliable encoders for voltage and current adjustment
- Constant voltage/constant current
- Parallel operation with Active Current Sharing,
with up to 4
- units in master slave mode and single wire current
share
- Series Operation ... maximum 2 units with external
diodes
- Independent remote ON/OFF
- Remote enable/disable
- External analog programming and monitoring
- Optional isolated analog programming and monitoring
- Lab View and Lab Windows drivers
- Conformal coating option - “CC”
|
|
|
|
GEN-HALF
|

|
|
750W
half width, 1RU programmable |
- Highest Power Density available:
- 750W in a 1U half-rack size.
- Wide Range Input (85 - 265Vac
Continuous)
- Active Power Factor Correction
(0.99 typical)
- Output Voltage up to 600V, Current
up to 100A
- Built-in RS-232/RS-485 Interface
- Front Panel Lockout
- Last-Setting Memory
- High Resolution 16 bit ADCs &
DACs
- Reliable Encoders for Voltage
and Current Adjustment
- Constant Voltage/Constant Current
auto-crossover
- Parallel Operation with Active
Current Sharing
- Independent Remote ON/OFF and
Remote
- Enable/Disable
- External Analog Programming and
Monitoring
- Reliable Modular and SMT Design
- 19" Rack Mounted ATE benchtop
and OEM applications
- Side-by-side mounting of two
units in a 19” rack
- Optional Isolated Analog Programming
and Monitoring
- Optional IEEE 488.2 SCPI (GPIB)
Interface
- LabView® and LabWindows® drivers
|
|
|
|
XFR
|

|
|
1200W
or 2800W |
- Nineteen
1200 and 2800 watt models
- Zero
voltage "soft"
switching for high efficiency,
low noise and high reliability
- Analog
programming standard, optional
ISOL (isolated programming)
option
- Optional
internal 16-bit GPIB (IEEE
488) and RS-232 control
- Constant
voltage or constant current
operation with automatic
crossover and mode indication
- LabView®
and LabWindows® drivers
- OVP,
current limit, thermal protection
- Standby
mode
- Front
panel button preview of
voltage, current, OVP
- Remote/local
modes
- Remote
sense, 5 V line loss compensation
- CE,
CSA, UL approvals
|
|
|
|
ST
|

|
|
60W
- 300W , Single / Multi Output |
- Input options: 100/120/220/240 VAC
- Analog (A) or Digital (D) meter options
- Constant current/constant voltage operation
- Series or parallel operation
- Short circuit protection
- Coarse and fine voltage control
- Master/slave operation - option R
- Output ON/OFF remote control - option R
- Output current voltage controlloble by external
variable voltage or resistance - option R
- Voltage/current readback option
- The TP3000 series comes with two analog or
optional digital meters. All outputs are floating and
can be connected in parallel or series to get multiple currents
and voltages.
|
|
|
|
MHY
|

|
|
60W
- 330W , Single / Multi Output |
- Variable
DC Power Supplies
- Low
Cost
- 3.5
Digits LCD display for voltage
and current
- Single
and Dual output
- Variable
voltage and current control
- Coarse
and fine adjustment
- Dual
output models with fixed
third output
- Dual
Input Voltage 110/220VAC
+/-10%
|
|
|
|
S-XDS
|

|
|
5KW
, 10KW , 15KW Single output |
- Compact
Modular DC Power: Uses less
rack space compared to other
DC supplies of similar power
level.
- Modular
construction supports 5,
10 and 15 KW versions.
- Wide
Range of Applications Telecommunications,
automotive, industrial and
commercial applications.
- Built-in
Measurements Voltage, current
and power readback capability
standard.
- Fast
Transient Response Capable
of driving demanding loads.
- Standard
RS232C Interface and optional
GPIB.
- Instrument
drivers and software support
for easy system integration.
|
|
|
|
XKW
|

|
|
1000W
- 3000W |
- Switched mode design.
- Thermal shutdown.
- Overvoltage protection.
- V & A meters.
- Voltage and current control.
- CV or CC operation.
- GPIB interface.
- Safety: CSA, UL.
- EMC approved.
|
|
|
|
XDC
|

|
|
6KW
- 12KW |
- Wide input 3 phase 208 VAC or 415 VAC
- Power factor corrected 0.9
- CE marked
- Constant power mode
- Overvoltage protection with adjustment 5% to
103%
- Digital processing with 16-bit control for
high accuracy
- Ten store/recall set-up locations
- Digital keypad and encoded knobs for fast front
panel operation
- Nine self-protection mechanisms
- Isolated analog programming and readback standard
- RS-232 standard
- LabView and LabWindows drivers
- CANbus communications link option for multi
unit current sharing sharing (master slave) and addressing
|
|
|
|
ESS |

|
|
10KW
- 15KW |
- Three phase input (various options)
- 10Kw and 15Kw output power
- Output voltage options from 7.5 ~ 600 VDC
- Front panel adjustable OVP
- Short circuit protection
- Thermal protection includes LED indicators
- Pulse by pulse current limit for fast recovery
- Series or parallel operation of units
- Transient protection
- Phase loss detection (neutral loss detection
is included above 208 VAC input models)
- Soft start
- Power factor corrected 0.9
- Voltage and current programming monitoring
are 0-5V standard (0-10V optional)
- UL and CE approval on some models
- CV and CC with automatic crossover with
LED indicators
- Choice of analog or digital meters
- 19in x 5U rack mounting
|
|
|
|
SR-HV |
|
|
300W
- 15KW , 1KV -150KV |
- Advanced
High Voltage Power Supplies
from 1KV up to 150KV
- Continuous
adjustable Voltage &
Current
- Customised
voltage and current ratings
available
- Full
protection against arcs,
overloads and short circuits
- Compact
design using Double Resonance
Technology (ZVC)
- V
& C Setting and Monitoring
from front panel or Remote
- Automatic
crossover
- Over
Current Limitation and Protection
functions
- Remote,
Inhibit & Interlock
functions
- Polarity
display
- Safety
switch key
|