The Quint Series of single phase units range in power from
3.5A to 40A and will all operate off a wide input of
85~264VAC.
There is also the added advantage of a double dip coating
where the units have a conformal coat for optimum protection
in extreme environments such as dust, corrosive gases or
even 100% humidity.
This also protects the unit against breakdowns due to
creepage currents caused by corrosion and electro-chemical
migration.
Another feature is the Selective Fuse Breaking technology
which allows for fast tripping of standard circuit breakers with
power reserves of up to six times the nominal current for 12ms.
Faulty current paths are switched off selectively, the fault is
located the important systems paths remain in operation.
An example of how this advanced system works is a frayed
display cable - the fuse trip, the lower level display is dark.
The controller, sensors and actuators continue to operate
without interruption and production continues.
Comprehensive diagnostics are provided through constant
monitoring of the output voltage and output current.
This preventive function monitoring visualises critical operating
states and indicates them to the controller before errors occur.